Testing.

Laboratory measurement.



BS EN ISO 10140-2:2010 ‘Acoustics. Laboratory measurement of sound insulation of building elements. Measurement of airborne sound insulation’, formerly BS EN ISO 140-3: 1995, is the internationally accepted method for testing and is referred to in the Part E Approved Document. 

A full-scale sample (doorset or door assembly) is installed within a separating wall of known sound reduction within a split chamber. Sound is generated within one side of the chamber at frequencies varying from 50 Hz to 10,000 Hz.

A receiving unit in the other side of the chamber measures sound reduction resulting from both wall and sample in 3rd octave bands. The level of reduction for the doorset/assembly alone is then calculated.
Measurements from the test are evaluated in accordance with BS EN ISO 717/1, formerly BS 5821 :Part 1. A series of standard reference curves is applied to the range 100 Hz – 3150 Hz until unfavorable deviation is as large as possible, but not exceeding 32 dB (This covers the human speech range - other specific noise problems, such as a generator hum, may need specific testing at the appropriate frequencies, falling outside the standard). The figure at 500 Hz is taken to provide a usable interpretation of the results in the form of a ‘weighted sound reduction index’, the Rw figure expressed in RwdB. This is a single figure value that identifies the acoustic performance of the doorset/assembly.

It should be remembered that performance values quoted for products and ranges are based on laboratory test results: on-site testing will generally produce lower results.

Please contact the Technical Sales Department for further advice. 

Responsive image

Responsive image

Talk to us to see how we can help you.

Our highly skilled team is always happy to share its technical expertise, whether over the phone or face-to-face.
Or call us on 01623 343111