Edge detailing, intumescents & seals.



Plasform transoms.

Transoms are available for use with fanlights and with overpanels if required. Overpanels for single or double doors can be accommodated without transoms and are manufactured with plain meeting stiles or with an applied astragal to the overpanel. Please see typical combinations and sections opposite.

Responsive image

Responsive image

  



Edge detailing

The Plasform range utilises a postformed edge detail which conceals hardwood lippings. Doors are fully encapsulated and maintenance free with 6mm radii postformed edges for PVC and 12mm radii for laminate. The 'softer' radiused vertical edges Plasform contribute to user-safety.

  



Edge detailing

The Plasform range utilises a postformed edge detail which conceals hardwood lippings. Doors are fully encapsulated and maintenance free with 6mm radii postformed edges for PVC and 12mm radii for laminate. The 'softer' radiused vertical edges Plasform contribute to user-safety.

Responsive image



Where pairs of doors are used with an overpanel but with an overpanel but without transom, steel angle stops are fitted for the doors to close against.

Responsive image

Responsive image




Astragals and angle stops
For pairs of doors, PVC astragals are required to cloak meeting stiles for sound reduction at 38 RwdB and radiation areas.




Astragals and angle stops
For pairs of doors, PVC astragals are required to cloak meeting stiles for sound reduction at 38 RwdB and radiation areas.

Responsive image



Fire and smoke
For fire rated doors, intumescent seals (tested to BS 476 Part 22) are fitted to the postformed edge and door head. Perimeter fire seals are essential to performance and form an integral part of the doorset fire rating, irrespective of stop size. There are two types available: intumescent and intumescent and smoke seal combined. These systems incorporate exposed intumescent strips to the doorleaf or overpanel. In Plasform® doorsets the intumescent strip is used as a colour contrast stripe on the leading door edge to comply with the Equality Act. Use of a combined intumescent and smoke seal instead of an intumescent only will provide smoke protection in accordance with BS 476 Part 31.1,‘Requirement for Cold Smoke Protection’, providing the gap at the bottom of the door does not exceed 3mm. If it does, an additional threshold seal will be required.

Non-fire
Regardless of fire rating, an intumescent joining strip is used between the two facings of the PlasformR door. At the meeting stile of pairs of doors, bladed seals
are used to block the sightline.

Acoustic
It is possible to factory-fit recessed drop seals into the bottom of the door leaf to meet sound reduction criteria.

Drop seals should be factory-fitted at the bottom of the door to close the gap with the floor when the door is closed using a mechanical system. This may be useful for smoke containment and low level acoustic control, particularly where the requirements for disabled accessibility call for an unimpeded floor surface. Where supplied and fitted by others, we must be informed early to adjust the door construction to accommodate this. Drop seals cannot be applied to doors installed in wet areas.

Air pressure balancing
Factory-fit recessed drop seals can be added into the bottom of the door leaf to meet air control criteria. Air leakage test results to BS 476 Part 31.1 under various
pressure differentials are available for air balancing calculations.

Responsive image

Responsive image

Responsive image




Ecoguard™
The newly developed wedge-shaped Ecoguard® seal is designed for application between the gaps of a doorframe and the surrounding wall during installation to improve building safety. Its compressible nature ensures a precise and dry fit can be achieved in varying gap widths without theneed for messy intumescent mastic.Ecoguard® is a fully certified product tested in accordance with BS 476 part 22 and provides an even coverage around the frame that is guaranteed to meet all relevant fire safety regulations. Fire tested to BS standards with Ecoguard® fitted on either side of the door for 30 minutes and both sides for 60 minutes. Ecoguard® also meets BS smoke performance criteria without the application of any additional sealing and meets EN standards for acoustics.

These characteristics are printed on each strip so contractors can be reassured it will satisfy building control officers without the need for further investigation – where mastic has been used they have to invasively check it has been applied to the correct depth, causing additional repair work on-site.




Ecoguard™
The newly developed wedge-shaped Ecoguard® seal is designed for application between the gaps of a doorframe and the surrounding wall during installation to improve building safety. Its compressible nature ensures a precise and dry fit can be achieved in varying gap widths without theneed for messy intumescent mastic.Ecoguard® is a fully certified product tested in accordance with BS 476 part 22 and provides an even coverage around the frame that is guaranteed to meet all relevant fire safety regulations. Fire tested to BS standards with Ecoguard® fitted on either side of the door for 30 minutes and both sides for 60 minutes. Ecoguard® also meets BS smoke performance criteria without the application of any additional sealing and meets EN standards for acoustics.

These characteristics are printed on each strip so contractors can be reassured it will satisfy building control officers without the need for further investigation – where mastic has been used they have to invasively check it has been applied to the correct depth, causing additional repair work on-site.

Responsive image

Talk to us to see how we can help you.

Our highly skilled team is always happy to share its technical expertise, whether over the phone or face-to-face.
Or call us on 01623 343111