Toggle navigation
Toggle navigation
Design & Technical
leaderflush shapland
Design.
Market sectors
>
Health
>
Education
>
Commercial
>
Leisure
>
Residential
>
Performance
>
Fire & smoke
>
Acoustics
>
Security
>
Strength & durability
>
Anti-microbial
>
Radiation shielding
>
Finger protection
>
Privacy
>
Technical.
Leaderflush Shapland
Technical resources
>
Technical guide
>
Standards & legislation
>
Literature & downloads
>
Veneer selector
>
Clear widths calculator
>
Frame drawings
>
Light reflectance values
>
Doorset solutions
>
Integrated
>
Plasform
>
Pivette
>
Designer
>
Sentinel
>
Laidlaw Architectural Ironmongery
>
>
Laidlaw Architectural Ironmongery
>
>
Technical Resources
Doorsets technical.
Technical guide
>
Standards & legislation
>
Literature & downloads
>
Veneer selector
>
Clear widths calculator
>
Frame drawings
>
Light reflectance values
>
>
>
>
>
>
>
Design Magazine
Design magazine
Case studies & project gallery
>
News
>
Contact Us
About Us
Close
Design.
Let's specify.
Let's specify - designer.
01 Performance
02 Configurations & handings
03 Dimensioning
04 Finishes
05 Glazing beads & systems
06 Vision panels
07 Privacy vision panels & air transfer grilles
08 Frames
09 Extension linings, fanlights, overpanels & glazed screens
10 Edge detailing, intumescents & seals
Let's specify - designer.
V
01 Performance
02 Configurations & handings
03 Dimensioning
04 Finishes
05 Glazing beads & systems
06 Vision panels
07 Privacy vision panels & air transfer grilles
08 Frames
09 Extension linings, fanlights, overpanels & glazed screens
10 Edge detailing, intumescents & seals
Integrated doorsets
Doorset solutions
Designer
Specify
Dimensioning
Dimensioning.
Designer doorsets are available in a range of configurations and handings to suit all project requirements.
The Designer range is available in a multitude of maximum sizes depending on the configuration and performance specified.
Configuration, size, construction and performance characteristics are all interrelated. Specific size ranges for
particular products can be found in
BWF CERTIFIRE or BM TRADA Q Mark data sheets available on the literature & download section.
Leaderflush Shapland manufactures all door leaf sizes to suit individual requirements.
Maximum certificated doorset sizes for fire performance – sizes are displayed in mm
Maximum certificated doorset sizes for fire performance – sizes are displayed in mm
Fire rating
Single action single leaf
Single action double leaf
Double action single leaf
Double action double leaf
Single leaf with overpanel (single and double action) no transom
Double leaf with overpanel (single and double action) no transom
Single leaf with overpanel (single and double action) transom required
Double leaf with overpanel (single and double action) transom required
Viscount (all variants)
30
915 x 2649 or 1152 x 2130 (2.45m2)
915 x 2449 or 1052 x 2130 (2.24m2)
N/A
N/A
max 2000 high overpanel
max 1500 high overpanel
max 2000 high overpanel
max 1500 high overpanel
Viscount (all variants)
60
900 x 2424 or 1025 x 2150 (2.22m2)
900 x 2224 or 925 x 2150 (2.00m2)
N/A
N/A
max 2000 high overpanel
max 1500 high overpanel
max 2000 high overpanel
max 1500 high overpanel
V90
90
915 x 2300 or 990 x 2150 (2.13m2)
915 x 2200 or 940 x 2150 (2.02m2)
N/A
N/A
N/A
N/A
max 2000 high overpanel
max 1500 high overpanel
V120
120
915 x 2135 (1.95m2)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Enduracor
30
1000 x 2925 or 1170 x 2500 (2.93m2)
1000 x 2925 or 1170 x 2500 (2.93m2)
1000 x 2925 or 1170 x 2500 (2.93m2)
1000 x 2925 or 1170 x 2500 (2.93m2)
max 1000 high overpanel
max 600 high overpanel
max 2000 high overpanel
max 2000 high overpanel
Enduracor
60
1200 x 2889 (3.46m2)
1000 x 2700 (2.97m2)
990 x 2700 or 1100 x 2430 (2.67m2)
990 x 2700 or 1100 x 2430 (2.67m2)
max 1000 high overpanel
max 600 high overpanel
max 2000 high overpanel
max 2000 high overpanel
Lamcor (all variants)
30
900 x 3200 or 1120 x 2400 (2.88m2)
900 x 3050 or 1150 x 2400 (2.76m2)
N/A
N/A
max 1500 high overpanel
max 1500 high overpanel
max 1500 high overpanel
max 1500 high overpanel
Lamcor (all variants)
60
915 x 2571 or 970 x 2440 (2.37m2)
916 x 2259 or 971 x 2138 (2.08m2)
N/A
N/A
N/A
N/A
max 2000 high overpanel
max 1500 high overpanel
Audiodor 30 & Audiodor 32
30
1000 x 2925 or 1170 x 2500 (2.93m2)
1000 x 2925 or 1170 x 2500 (2.93m2)
N/A
N/A
N/A
N/A
max 2000 high overpanel
max 2000 high overpanel
Audiodor 30 & Audiodor 32
60
1200x2889 (3.46m2)
1100x2700 (2.97m2)
1100x2700 (2.97m2)
1100x2700 (2.67m2)
N/A
N/A
max 2000 high overpanel
max 2000 high overpanel
Audiodor 35
30
915 x 2649 or 1152 x 2130 (2.45m2)
N/A
N/A
N/A
N/A
N/A
max 2000 high overpanel
N/A
Audiodor 35
60
915 x 2300 or 1026 x 2047 (2.10m2)
865 x 2255 or 926 x 2120 (1.96m2)
N/A
N/A
N/A
N/A
max 2000 high overpanel
max 1500 high overpanel
Audiodor 39
60
926 x 2275 (2.11m2)
926 x 2275 (2.11m2)
N/A
N/A
N/A
N/A
N/A
N/A
Audiodor 38/40/44 super –
(Latched)
30
1000 x 2188 (2.19m2)
1000 x 2188 (2.19m2)
N/A
N/A
N/A
N/A
max 1500 high overpanel
max 1500 high overpanel
Audiodor 38/40/44 super –
(Unlatched)
30
926 x 2188 (2.03m2)
922 x 2135 or 925 x 2130 (1.97m2)
N/A
N/A
N/A
N/A
max 1500 high overpanel
max 1500 high overpanel
Sentinel (all variants)
30
1026 x 2100 (2.16m2)
1026 x 2100 (2.16m2)
N/A
N/A
N/A
N/A
N/A
N/A
Sentinel (all variants)
60
1026 x 2100 (2.16m2)
1026 x 2100 (2.16m2)
N/A
N/A
N/A
N/A
N/A
N/A
Safehinge – Enduracor
30
920 x 2517 or 1105 x 2100 (2.31m2)
908 x 2423 or 1051 x 2100 (2.20m2)
920 x 2467 or 1080 x 2100 (2.26m2)
908 x 2373 or 1026 x 2100 (2.15m2)
N/A
N/A
N/A
N/A
Safehinge – Enduracor
60
850 x 2384 or 979 x 2100 (2.02m2)
850 x 2284 or 929 x 2100 (1.94m2)
850 x 2334 or 954 x 2100 (1.98m2)
850 x 2234 or 904 x 2100 (1.89m2)
N/A
N/A
N/A
N/A
Safehinge – Lamcor
30
920 x 2517 or 1105 x 2100 (2.31m2)
908 x 2423 or 1051 x 2100 (2.20m2)
N/A
N/A
N/A
N/A
N/A
N/A
Safehinge – Lamcor
60
850 x 2384 or 979 x 2100 (2.02m2)
850 x 2284 or 929 x 2100 (1.94m2)
N/A
N/A
N/A
N/A
N/A
N/A
AV1/AV2
30
1167 x 2275 (2.66m2)
1047 x 2275 (2.39m2)
N/A
N/A
N/A
N/A
max 1000 high overpanel
max 1000 high overpanel
AV1/AV2
60
926 x 2275 (2.11m2)
926 x 2275 (2.11m2)
N/A
N/A
N/A
N/A
max 1000 high overpanel
max 1000 high overpanel
Leadline
30
1170 or 2300 (2.70m2)
1170 or 2300 (2.70m2)
N/A
N/A
N/A
N/A
N/A
N/A
Leadline
60
926 x 2275 (2.11m2)
926 x 2275 (2.11m2)
N/A
N/A
N/A
N/A
N/A
N/A
Pivette
30
682 x 2040 – primary leaf - max area (1.39m2)
340 x 2040 – seconday leaf - max area (0.69m2)
N/A
N/A
N/A
N/A
N/A
N/A
The drawings below set out the terminology for dimensioning doorsets.
The maximum clearance permitted from the top of the finished floor to the underside of the door leaf is 10mm for 30 and 60 minutes fire resistance and 5mm for 90 and 120 minutes. For smoke control the clearance is 3mm.
Effective clear widths.
The clear opening width is measured up to any projecting door item including furniture as shown below. A space of at least 300mm is generally required next to the leading edge of the door to enable wheelchair users to reach and grip the handle, unless the door is power operated. Door opening furniture should be operable with one hand (e.g. lever action).
Please note: Weatherboards where fitted should be taken into consideration.
Effective clear widths.
The clear opening width is measured up to any projecting door item including furniture as shown below. A space of at least 300mm is generally required next to the leading edge of the door to enable wheelchair users to reach and grip the handle, unless the door is power operated. Door opening furniture should be operable with one hand (e.g. lever action).
Please note: Weatherboards where fitted should be taken into consideration.
Talk to us to see how we can help you.
Our highly skilled team is always happy to share its technical expertise, whether over the phone or face-to-face.
Contact us today
Request a callback
Or call us on
01623 343111
Request a callback
Thank you.
A member of the respective department will get in touch with you shortly.
Regards,
Leaderflush Shapland Laidlaw Team
Request a callback
Thank you.
A member of the respective department will get in touch with you shortly.
Regards,
Leaderflush Shapland Laidlaw Team
Top